Products/M-Center/Heat and water meters

M-CenterApplication

Remote reading of heat and water meters via M-Bus

Almost every wired heat, cooling and water meter speaks M-Bus. The EMU M-Center reads these meters together with the electricity meters, from any manufacturer, and passes the values on to billing, control system and energy management.

Key facts

  • One M-Center reads up to 250 M-Bus meters: heat, cooling, water, gas and electricity.
  • The meter search runs automatically by primary or secondary address.
  • For meters from other manufacturers there are device drivers that can be imported and adapted.
  • With OBIS codes, water and heat values sit at fixed addresses and topics.
  • Export as CSV, JSON or Excel via (s)FTP or e-mail, plus MQTT, BACnet IP and Modbus TCP.

What a heat meter delivers via M-Bus

A heat meter measures more than a meter reading. Via M-Bus it typically delivers energy, volume, flow and return temperature, flow rate and power. Which values the telegram contains exactly is defined by the manufacturer. The M-Center reads the telegram and assigns the values to the registers.

For passing them on there are fixed OBIS codes. This way the reading of a heat meter is always in the same place, even if meters from different manufacturers are installed in the building:

Meter typeOBIS codeReading
Cold water8-0:1.0.0Volume, meter reading
Hot water9-0:1.0.0Volume, meter reading
Heat4-0:1.0.0Meter reading
Heat4-0:3.1.0 / 4-0:3.2.0Flow and return temperature
Cooling5-0:1.0.0Energy, meter reading
Combined heat/cooling6-0:1.0.0 and 5-0:1.0.0Energy in the heating and in the cooling range
Gas7-0:3.0.0Volume, meter reading
Extract from the OBIS table in the M-Center manual

How the meters get into the M-Center

  1. Connect the meters to the M-Center with a two-wire M-Bus cable. J-Y(ST)Y 2×2×0.8 mm is recommended, shielded where possible. Star, tree and line are permitted; polarity does not matter.
  2. Start the search in the web interface. 2400 baud is recommended. The search by secondary address runs over all possible addresses and finds every meter by its unique identifier.
  3. Check the meters found. For meters from other manufacturers, the M-Center uses device drivers. If one is missing, it can be created or imported in the web interface.
  4. Enter OBIS codes for the registers that are to be passed on.
  5. Set the readout interval and configure the target systems.

For the readout interval, follow the recommendation of the meter manufacturer. The lower limit is set by the installation itself: if a run over all meters takes longer than 15 minutes, choose a longer interval or set individual intervals for single meters.

Keep an eye on the bus load

Every meter loads the bus with about 1.5 mA (one unit load). The M-Center supplies 450 mA continuous load at 230 V AC and up to 1.6 A at 24 V DC. For 250 unit loads, therefore plan with 24 V DC. The maximum cable length is 5000 m at 100 nF/km and no more than 90 Ω. How the calculation works is explained in our article on M-Bus bus load (in German).

Where the values go

TargetRouteLicence
Billing service providerCSV, JSON or Excel via (s)FTP or e-mailAdvanced Exporter for processed exports
Building managementBACnet IP or OPC UABACnet IP or OPC UA licence
PLC and control systemModbus TCPModbus TCP server licence
Dashboard, cloud, home automationMQTTMQTT licence
Energy managementJoulio-Web–

The routes do not exclude each other. The M-Center reads each meter once and serves all targets in parallel.

Order numbers

ItemArticle numberShop
M-Center for 20 M-Bus devices210.000.00Shop: EMU M-Center 210.000.00 →
M-Bus licence 20 → 60 devices210.020.01Shop: M-Center M-Bus-Lizenz 20 → 60 Geräte 210.020.01 →
M-Bus licence 20 → 120 devices210.020.02Shop: M-Center M-Bus-Lizenz 20 → 120 Geräte 210.020.02 →
M-Bus licence 20 → 250 devices210.020.03Shop: M-Center M-Bus-Lizenz 20 → 250 Geräte 210.020.03 →
Advanced Exporter licence210.300.06

Order online in the EMU Metering shop.

Frequently asked questions


Can the M-Center read meters from any manufacturer?

Meters with wired M-Bus to EN 13757, yes. To assign the values, the M-Center uses device drivers. Drivers can be imported, exported and created. If in doubt, send us the manufacturer and type.

Does the M-Center also read wireless meters?

The M-Center itself reads wired meters via M-Bus, Modbus RTU, Modbus TCP and S0. For wireless meters in existing buildings without cables, we use LoRaWAN with a separate gateway.

How do I find the primary address of a meter?

You don’t have to. The search by secondary address finds every meter by its unique identifier. The search by primary address is faster and can be limited to an address range.

What happens if a meter does not respond?

The M-Center logs every failed readout. Via Modbus TCP there are dedicated status registers with the timestamp of the last successful readout.

Read more


SEITEEMU M-CenterProduct TXTCalculating M-Bus bus loadBlog article SEITEM-Bus data logger for apartment buildingsApplication PDFM-Center manualPDF

Read meters remotely?


Send us the meter list with manufacturer and type. We will check the drivers and propose the licences.

Phone
+41 (0)41 545 03 00

Technical support
helpdesk [at] emuag.ch